ITEM NO DHS-100 DHS-225 DHS-500 DHS-010 DHS-013 |
|
Size of studio D*W*H
450*450*500 500*600*750 800*700*900 1000*1000*1000 1000*1000*1300 |
|
Temperature range |
0℃--100℃ |
|
Humidity range |
30-98% R.H |
|
Fluctuations/uniformity |
≤±0.5℃/≤±2℃ |
|
Humidity deviation |
+2, -3% R.H |
|
Heating time |
0℃--100℃ about 35min |
|
Cooling time |
100℃---0℃ about 40min |
|
Controller: imported Microcomputer Integrated temperature and humidity controller |
|
Precision range set precision: temperature±0.1℃ instructed precision: temperature±1% R.H humidity: ±1% R.H |
|
Temperature and humidity sensor |
platonic resistance PT100 /MV |
|
Heating system: all independent systems, Ni-Cr alloy, heating heaters |
|
Add humidity system: External insulate style, evaporation in stainless steel surface type Add humidity machine |
|
Dehumidification system: evaporator coil contacts dew-point temperature Dehumidification way laminar |
|
Water supply system: automatically control to add humidity and supply water |
|
And can recover the waste water to cut down expense |
|
Cooling system: all :closed one way /multi ways wind-cooled Compression refrigeration |
|
(brand: “TAI KANG” from France) |
|
Cycling system: high temperature resistance, low noisy air conditioning motor |
|
multi-leaf centrifugal wind round |
|
Material of outside box: carbon steel plate of good quality, which is deal with electrostatic phosphate powder-coating,SUS304 stainless steel plate with veins in the surface |
|
Material of inside box:SUS304 stainless plate with mirror surface of good quality |
|
Material of heat preservation |
polyurethane foaming glass fiber cotton |
|
Heat insulation doorframe: double high, low temperature-resistance, anti-aging rubber sealing bar |
|
Standard configuration |
glass vision window for lighting(1set) |
|
Sample rack 2pcs 1 test holes (25, 50,100mm) |
|
Safety protections: have memory in situation of Leakage, short-circuit |
|
over-temperature of the electric machinery and lack of water |
|
Also have memory when Over-current/voltage of compressor happens. |
|
Power supply voltage:AC380V±10% 50±0.5HZ three-phase five-wire system |
|
Temperature of the environment |
5℃--+30℃≤85% R.H |
|
P.S 1 “DHS”is the pattern symbol of low temperature constant temperature and humidity test chamber.
2, All the data are taken in condition of 25℃(QT) and the working studio has no load
3, We can make nonstandard low temperature constant temperature and humidity test chamber according to the demand of the customer. |